Item(s) Added To Your Bag

Metravi Pro Solar-2A Digital TRMS AC|DC Clamp Meter

Click To Zoom

Metravi Pro Solar-2A Digital TRMS AC|DC Clamp Meter

Metravi Pro Solar-2A Digital TRMS AC|DC Clamp Meter

(Based On 10 Reviews)

The Metravi PRO Solar-2A is a professional T-RMS Industrial Clamp Meter which measures upto 1500V DC and 1000V AC, making it ideal for high voltage applications, including Solar, Photovoltaic, EV, Power, Motor, etc. applications. 

Request Callback

Order In Bulk

Generate Quote

100% ORIGINAL Products Details

100% ORIGINAL Products

SECURE Payments Details

SECURE Payments

₹ 10,598.00

(GST inclusive price) i
  • Base Value: ₹ 8981.4
  • GST: (18) % ₹ 1616.6
  • Total Value ₹ 10598

₹10,598.00

( - 0% OFF )

Need Help ?

Our Client Care Managers Are On Call 24/7 To Answer Your Question.

Description

Key Features

  • Display: 3-3/4 digits (4000 counts) backlit LCD
  • Jaw Opening: 2” (52mm) approx.
  • PV DC Voltage: 400mV / 4V / 40V / 400V / 1500V
  • Accuracy: ± (1% + 3d)
  • AC Voltage T-RMS: 4V / 40V / 400V / 1000V
  • Accuracy: ± (1.2% + 5d)
  • AC Current : 400A / 1200A
  • Accuracy: ± (3.0% + 3A)
  • DC Current: 400A / 1200A
  • Accuracy: ± (3.0% + 3A)
  • Resistance: 400Ω / 4kΩ / 40kΩ / 400kΩ / 4MΩ / 40MΩ
  • Accuracy: ± (1.0% + 4d)
  • Frequency: 10Hz to 100kHz / 40Hz to 1kHz
  • Accuracy: ± 1.0% ±5 digits
  • Capacitance: 40nF / 400nF / 4µF / 40µF / 400µF
  • Accuracy: ± (3.5% + 10d)
  • Diode Testing
  • Continuity Test
  • Over-range Protection
  • Auto-ranging
  • Safety: For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (2001): EN61010-1 (2001) Over voltage Category III 1000V and Category IV 600V, Pollution Degree

 

What's in the box?

  •  Digital TRMS AC|DC Clamp Meter

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0

Product Specifications

General Specification
Clamp jaw opening2” (52mm) approx
Display3-3/4 digits (4000 counts) backlit LCD Buzzer.
Continuity CheckSounds at less than (50±30)W
Diode TestTest current of 0.9mA typical; Open circuit voltage
approx 3.2V DC typical.
Low Battery Indication“ ” is displayed
Over-range Indication“OL” is displayed
Measurement Rate3 times per second, nominal.
PEAKCaptures peaks > 1ms.
Temperature sensorType-K thermocouple.
Input Impedance10MW (VDC and VAC)
BatteryOne 9 Volts (NEDA 1604) battery
Operating Temperature41°F to 104°F (5°C to 40°C)
Storage Temperature 4°F to 140°F (-20 to 60°C)
Operating HumidityMax 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F (40°C)
Storage Humidity<80%
Operating Altitude7000 ft. (2000 meters) maximum
Auto power OFFAfter approx. 15 minutes.
Dimensions & Weight270mm (H) x 107mm (W) x 50mm (D), 554 gms
SafetyFor indoor use and in accordance with the requirements for double insulation to
IEC1010-1 (2001): EN61010-1 (2001) Over voltage Category III 1000V and Category
IV 600V, Pollution Degree 2.

 

Technical Specification
 RangeAccuracy
(% of reading + digits)
Resolution
PV DC Voltage400mV± (1% + 10d) 0.01mV
4V± (1% + 3d) 1mV
40V± (1% + 3d) 10MV
1500V ± (1% + 3d) 1V
AC Voltage T-RMS4V ± (1.2% + 5d) 1mV
40V± (1.2% + 5d)10MV
400V± (1.2% + 5d) 100MV
1000V± (1.2% + 5d) 1V
AC Current400A ± (3.0% + 3A)100mA
1200A± (3.5% + 6d)1A
DC Current400A± (3.0% + 3A)100mA
1200A ± (3.5% + 6d) 1A
Resistance400W± (1.0% + 4d) 0.1W
4kW± (1.5% + 4d) 1W
40kW± (1.5% + 4d) 10W
400kW± (1.5% + 4d)100W
4MW± (1.5% + 4d)1kW
40MW± (2.0% + 4d)10kW
Frequency10Hz to 100kHz± 1.0% ±5 digits 
Duty Cycle(0.1% to 99.9%)± (1.2% + 5d) 0.1%
Temperature-20 to 100°C)± (2.0% +5°C) 1°C
(-4 to1832°F) ± (3.0% + 9°F) 1°F
Peak of AC Current400A± (4.0% + 5d)100mA
1200A± (4.0% + 5d) 1A
Capacitance40nF± (5.0% + 20d)1nF
400nF ± (3.5% + 10d) 10nF
4μF± (5.0% + 10d) 100nF
40μF± (5.0% + 10d) 1μF
400μF± (5.0% + 10d) 10μF 

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0